HVAC Cooling Tonnage Calculator

Total Floor Area (Sq. Ft.)
Climate & Insulation Rating
Average Occupants (People)
Equipment Heat Load (Watts)
Calculated HVAC Scope
50.8 TR
Calculated Net Cooling Tonnage
610,000 BTU/hr
Total Heat Load
60 TR VRF/Chiller Plant
Recommended Standard Commercial Equipment Size
20,320 CFM
Recommended Airflow Capacity
⚡ Dedicated Subdomain Tools ASHRAE / IS 1391
Calculate detailed sensible vs latent heat loads, psychrometric coil ADP, or chiller plant lifecycle payback on our dedicated portal:

Electrical Substation & Transformer Sizing

Lighting Load (kW)
Raw Power Sockets Load (kW)
HVAC Compressor & Pumps (kW)
Machinery & Motor Loads (kW)
Diversity Factor
Target Power Factor
Substation Engineering Output
200 kVA Substation
Recommended Standard Transformer Rating
155 kW
Total Connected Load
124 kW
Peak Maximum Demand
200 kVA DG Backup
Recommended DG Generator Capacity
⚡ Dedicated Subdomain Tools IS 2026 / ISO 8528
Calculate core & copper losses, transformer impedance, generator step-loading, or busbar fault bracing:

Cable Sizing & Voltage Drop Calculator

Feeder Load (kW) — 3 Phase 415V
Route Cable Length (Meters)
Load Power Factor
Cable Engineering Selection
35 sq.mm 4C Armored
Recommended XLPE Aluminum Cable
122.8 Amps
Full Load Current
7.35 V (1.77%)
Calculated Route Voltage Drop
PASSED (IS 7098 Compliant < 3%)
Voltage Drop Compliance Status
⚡ Dedicated Subdomain Tools IS 7098 / IS 3043
Calculate cable sizing with soil/ambient derating, short-circuit withstand, and earth conductor strip sizing:

APFC Capacitor Bank Calculator

Active Facility Load (kW)
Initial Power Factor (Measured)
Target Power Factor
APFC Panel Sizing
102 kVAR
Required Compensation Capacity
125 kVAR APFC Panel
Recommended Automatic APFC Panel Size
₹ 367,200 / Year
Estimated Power Factor Penalty Savings
⚡ Dedicated Subdomain Tools IS 13585 / IEC 60831
Calculate multi-stage APFC step distribution, detuned harmonic reactors (7%/14%), and motor MCC protection:

Duct Sizing & Airflow CFM

Required Airflow Rate (CFM)
Design Air Velocity (FPM)
Duct Dimensions Output
35" W × 23" H
Recommended Rectangular Duct Size
8.00 sq.ft
Cross Sectional Duct Area
22 SWG GI
Recommended Galvanized Sheet Gauge
⚡ Dedicated Subdomain Tools SMACNA / IS 655
Calculate equivalent circular/flat-oval duct, total ESP static pressure loss, or chilled water hydronics:

Solar Panel & Rooftop PV Sizing

Monthly Electricity Bill Units (kWh)
Average Peak Sun Hours / Day
Rooftop Solar Plant Output
41.7 kWp Solar Plant
Recommended Rooftop PV Capacity
3,750 sq.ft
Required Shade-Free Roof Area
60,882 kWh / Year
Estimated Annual Clean Energy Generation
3.9 Years
Estimated Financial Payback Period
⚡ Dedicated Subdomain Tools MNRE / IEC 61724
Calculate solar inverter capacity, generation degradation, battery bank autonomy, and UPS backup:

Fire Fighting Pump Head Calculator

Occupancy & Hazard Classification
Building Height (Meters)
Active Hydrant Outlets
Fire Fighting Pump Sizing
60 HP Main Electric Pump
Main Fire Pump Motor Rating
10,800 LPM (2,851 GPM)
Main Hydrant Flow Rate
95 Meters Head
Required Total Dynamic Head (TDH)
10 HP Jockey Pump
Pressure Maintenance Jockey Pump
⚡ Dedicated Subdomain Tools NBC 2016 / ISO 14644
Calculate high-rise stairwell pressurization airflow, door leakage, or cleanroom ACPH & HEPA air filtration:

Complete 20-Calculator Engineering Directory

Full-featured engineering calculators hosted on our dedicated subdomain tools.rsele-hvac.com with complete standards references, downloadable technical sheets, and BOQ estimation.

⚡ Visit Portal Hub ↗

Google Business Profile — Verified Reviews

Real engineering performance and project delivery feedback from plant heads, facility directors, and commercial developers across North India.

G 4.9 ★★★★★ (Verified GBP)
⭐⭐⭐⭐⭐ Leave a Google Review →
Start Your Infrastructure Optimization
Get a technical assessment, cost optimization roadmap, and execution plan tailored to your facility.
Request Assessment Call +91 62399-13625 💬 WhatsApp +91 62399-13625